SKU | HI83314-02 |
---|
Product Name | Wastewater Multiparameter (with COD) Benchtop Photometer and pH meter - HI83314 |
---|
Quote Required | Yes |
---|
pH Range | Photometer |
---|
pH Resolution | Photometer |
---|
pH Accuracy | Photometer |
---|
pH Calibration | Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01) |
---|
pH Temperature Compensation | Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used |
---|
pH CAL Check (electrode diagnostics) | clean electrode and check buffer/check probe displayed during calibration |
---|
pH Method | Photometer |
---|
pH-mV Range | ±1000 mV |
---|
pH-mV Resolution | 0.1 mV |
---|
pH-mV Accuracy | ±0.2 mV |
---|
Absorbance Range | 0.000 to 4.000 Abs |
---|
Absorbance Resolution | 0.001 Abs |
---|
Absorbance Accuracy | ±0.003Abs @ 1.000 Abs |
---|
Ammonia Range | Low Range |
---|
Ammonia Resolution | 0.01 mg/L; 0.1 mg/L |
---|
Ammonia Accuracy | Low Range |
---|
Ammonia Method | Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method |
---|
Chemical Oxygen Demand Range | Low Range |
---|
Chemical Oxygen Demand Resolution | Low and Medium Range |
---|
Chemical Oxygen Demand Accuracy | Low Range |
---|
Chemical Oxygen Demand Method | Adaptation of the USEPA 410.4 ISO dichromate methods Mercury-free dichromate green method (LR & MR); dichromate method (HR) |
---|
Total Chlorine Range | 0.00 to 5.00 mg/L (as Cl2) |
---|
Total Chlorine Resolution | 0.01 mg/L |
---|
Total Chlorine Accuracy | ±0.03 mg/L ±3% of reading |
---|
Chlorine Method | Adaptation of the EPA 330.5 DPD method |
---|
Nitrate Range | 16 mm vial |
---|
Nitrate Resolution | 0.1 mg/L |
---|
Nitrate Accuracy | 16 mm vial |
---|
Nitrate Method | Adaptation of the cadmium reduction method |
---|
Nitrite Range | Freshwater Low Range |
---|
Nitrite Resolution | Freshwater |
---|
Nitrite Accuracy | Freshwater Low Range |
---|
Nitrite Method | Adaptation of the EPA Diazotization method 354.1 |
---|
Nitrogen, Total Range | Low Range |
---|
Nitrogen, Total Resolution | 0.1 mg/L; 1 mg/L |
---|
Nitrogen, Total Accuracy | Low Range |
---|
Nitrogen, Total Method | Chromotropic acid method |
---|
Phosphorous, Acid Hydrolyzable Range | 0.00 to 1.60 mg/L (as P) |
---|
Phosphorous, Acid Hydrolyzable Resolution | 0.01 mg/L |
---|
Phosphorous, Acid Hydrolyzable Accuracy | ±0.05 mg/L or ±5% of reading |
---|
Phosphorous, Acid Hydrolyzable Method | Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method |
---|
Phosphorous, Reactive Range | Low Range |
---|
Phosphorous, Reactive Resolution | 0.01 mg/L; 0.1 mg/L |
---|
Phosphorous, Reactive Accuracy | Low Range |
---|
Phosphorous, Reactive Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th edition and EPA method 365.2 (low range) Low Range |
---|
Phosphorous, Total Range | Low Range |
---|
Phosphorous, Total Accuracy | Low Range |
---|
Phosphorous, Total Resolution | Low Range |
---|
Phosphorous, Total Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th edition and EPA method 365.2 (low range) Low Range |
---|
Input Channels | 1 pH electrode input and 5 photometer wavelengths |
---|
pH Electrode | digital pH electrode (not included) |
---|
Photometer/Colorimeter Light Source | 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters |
---|
Photometer/Colorimeter Light Detector | silicon photodetector |
---|
Bandpass Filter Bandwidth | 8 nm |
---|
Bandpass Filter Wavelength Accuracy | ±1 nm |
---|
Cuvette Type | round, 24.6 mm |
---|
Number of Methods | 128 max. |
---|
GLP | calibration data for connected pH electrode |
---|
Display | 128 x 64 pixel LCD with backlight |
---|
Logging Type | log on demand with user name and sample ID optional input |
---|
Logging Memory | 1000 readings |
---|
Connectivity | USB-A host for flash drive; micro-USB-B for power and computer connectivity |
---|
Power Supply | 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) |
---|
Battery Type/Life | 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement |
---|
Environment | 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing |
---|
Weight | 1.0 kg (2.2 lbs.) |
---|
Dimensions | 206 x 177 x 97 mm (8.1 x 7.0 x 3.8") |
---|
Ordering Information | HI83314 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. |
---|